• Cables for ALHF-C LSZH CPR Cca Alarm Systems

    Intended for permanent installation inside buildings, and for temporary installation outdoors, used to connect the electrical devices in the intrusion detection system. Installation alongside Category 1 cables marked either 450/750 V or 0.6/1 kV is permitted, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. Installation in underground cable ducts is not permitted. The CPR Cca classification also permits use in environments with a higher fire risk (MEDIUM risk).
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • FROHR PVC Cables for Alarm Systems – Eca

    Fixed installation inside buildings, used to connect electrical equipment in an intrusion detection system. Installation alongside Category 1 cables marked as either 450/750 V or 0.6/1 kV is permitted, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. Installation in underground cable ducts is not permitted. The Eca CPR classification allows for use in environments with a higher fire risk (LOW risk).
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • FROHR XE PVC Double-Jacketed Alarm Cables – Eca

    Fixed installation indoors and outdoors; used to connect electrical equipment in an intrusion detection system. Installation alongside Category 1 cables marked either 450/750 V or 0.6/1 kV is permitted, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. Installation in underground cable ducts is permitted, provided protection is used. The Eca CPR classification allows for use in environments with a higher fire risk (LOW risk).
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • Rodent-resistant armored cables

    Designed for fixed installation indoors and outdoors, these cables are resistant to rodents and moisture and feature a braided steel armor between the first and second sheaths. Installation alongside Category 1 cables marked either 450/750 V or 0.6/1 kV is permitted, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. Installation in underground cable ducts is permitted, provided the cables offer excellent resistance to weathering. The Eca CPR classification also permits use in environments with a higher fire risk (LOW risk).
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
    UPON REQUEST
  • Bus Cables and Home Automation

    Fixed installation indoors and temporary installation outdoors; used for signal transmission in home automation Bus systems. Installation is permitted alongside Category 1 cables marked as either 450/750 V or 0.6/1 kV, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. Installation in underground cable ducts is not permitted. The Eca CPR classification also allows for use in environments with a higher fire risk (LOW risk).
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • Blue PVC Double-Jacketed Bus Cables

    Fixed installation indoors and temporary installation outdoors; used for transmitting BUS and RS485 signals. Installation is permitted alongside Category 1 cables marked as either 450/750 V or 0.6/1 kV, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. The double-jacket construction allows for installation in underground cable ducts, provided they are protected. The Eca CPR classification also permits use in environments with a higher fire risk (LOW risk).
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • RS-485 Data Cables, Types 9841–9842

    Fixed installation indoors and, on a non-permanent basis, outdoors as well; used for signal transmission via the RS485 interface. Installation alongside Category 1 cables marked either 450/750 V or 0.6/1 kV is permitted, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. Installation in underground cable ducts is not permitted. The Eca CPR classification also allows for use in environments with a higher fire risk (LOW risk).
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • Video Cable – 2-Wire Intercom Cable

    Fixed installation indoors and temporary installation outdoors; used to connect video intercoms to a 2-wire system. Installation is permitted alongside Category 1 cables marked as either 450/750 V or 0.6/1 kV, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. The Eca CPR classification also allows for use in environments with a higher fire risk (LOW risk).
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • Low-Loss HD Coaxial Cables

    Fixed indoor installation and temporary outdoor installation; used for the transmission of video signals in high-definition analog video surveillance systems (HD) video surveillance systems. Installation alongside Category 1 cables marked either 450/750 V or 0.6/1 kV is permitted, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. Installation in underground cable ducts is not permitted. The Eca CPR classification also allows for use in environments with a higher fire risk (LOW risk)

    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • LSZH Cat. 5e UTP-FTP Data Cables – LSZH UTP Cat. 5e 4x2xAWG24

    UTPCAT5LSZH

    Category 5E 4-pair F/UTP cable (100 ohms), shielded with aluminum tape, with a flame-retardant LSZH (Low Smoke Zero Halogen) jacket, tested up to 200 MHz. Suitable for the installation of Class D transmission channels.
    DESCRIPTION
    100-METER SPOOL
    500-METER REEL
    BOX
  • FTE29OHM16 Cable, EN 50200, PH 120, CEI 20-105 V2

    Shielded LSZH cable for signaling and control, fire-resistant (PH120), in accordance with CEI 20-105, V1, V2, and UNI 9795:2021. Suitable for connecting equipment in fixed automatic fire detection systems and manual fire alarm signaling systems, whether or not connected to fire suppression systems or other protection systems (both active and passive), intended for installation in buildings, regardless of their intended use.
    DESCRIPTION
    100-METER SPOOL
    200-METER COIL 
    500-METER REEL
  • EVAC FTS29OM16 Cable, EN 50200, PH 120, CEI 20-105 v2

    FTH2B

    Designed for fixed indoor installation and temporary outdoor installation; they can be used to interface with audio systems in EVAC voice evacuation systems. Designed to continue operating even in the presence of flames for up to 120 minutes. Installation is permitted alongside Category 1 cables marked either 450/750 V or 0.6/1 kV, with a nominal voltage to ground (Uo) of up to 400 V, in accordance with the UNEL 36762 standard. Installation in underground cable ducts is not permitted. The CPR Cca classification allows for use even in environments with a higher fire risk (MEDIUM risk).
    DESCRIPTION
    100-METER SPOOL
    500-METER REEL

Contact us for more information!